Spartan Noise Dosimeter Specifications
Model 730 Performance, Measured Values, and Mechanical Information
SPECIFICATIONS
|
Performance
|
Standards
|
ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2
|
Linear Operating Range
|
52 – 140 dB rms A-weighted
|
Dynamic Range
|
94 dB
|
Peak Range
|
78 – 143 dB Peak, C-weighted
|
Peak Weightings
|
A, C, Z
|
RMS Weightings
|
A, C, Z
|
Time Weightings
|
Slow, Fast, Impulse
|
Frequency Range
|
20 Hz to 10 kHz
|
Data Logging
|
Selectable 1 second or 1 minute samples
|
Logged Data
|
LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, TWA3, TWA5, Motion
|
Memory
|
8 GB internal
|
Communications
|
Bluetooth Low Energy 4.1
USB 2.0 (Micro-B connector)
|
Battery
|
Rechargeable Lithium Ion
|
Run Time
|
40 hours, typical
|
Charge Time
|
3 hours from full discharge
|
Charger
|
Qi-compliant wireless or USB
|
Compliance
|
CE, ROHS, WEEE
|
Motion
|
Overall motion percentage and bump
|
Languages
|
English, Spanish, Italian, French, Portuguese, German
|
Virtual Dosimeter
|
Virtual Dosimeters
|
4 independent with configurable LED indication
|
Exchange Rate
|
3, 4, 5, 6
|
Criterion Level
|
70.0 to 100.0 dB
|
Threshold
|
70.0 to 100.0 dB
|
Shift Time
|
1 to 24 hours
|
Alarms
|
2 independent with configurable indication
|
Measurement Results
|
Dose; ProjDose; LAVG; TWA(8); Proj TWA(8); Lex,8h; Lep,d; Proj Lep,d
|
Summary Measured Values (Common to all virtual dosimeters)
|
LωΤ (SPL), Lωeq (Leq), Lωpk (Lpeak), LωΤMax (Lmax), LωΤMin (Lmin) where
ω = A, C, or Z frequency weighting
Τ = F, S, or I time weighting
Lpeak, Lmax, & Lmin including time of occurrence
LC-A, Exposure (Pa2s & Pa2h), Motion
Exceedance count and time for 2 rms and 3 peak thresholds
Overload count, duration and percentage
|
Mechanical
|
Display
|
Color LCD 176 x 176 pixels, always on with low light sensor and front light
|
Ingress Protection
|
IP65
|
Keys
|
Four buttons
|
Weight
|
112 g (4.2 oz.) including clips and windscreen
|
Dimensions
|
85 x 54 x 39 mm (3.35 x 2.13 x 1.54 in.) dosimeter only
|
Microphone
|
¼-inch Model 375A03
|
Operating Temperature
|
–10 to +50 ℃ (14 to 122 ℉)
|
Operating Humidity
|
Up to 90% RH, non-condensing
|
1/1 Octave Filters (optional)
|
Standards
|
ANSI/ASA S1.11-2014; IEC 61260-1:2014 Class 1
|
Filters
|
31.5 Hz to 8 kHz
|
Linear Operating Range
|
42 to 140 dB @ 1 kHz
|
Measured Results
|
LZeq (Leq), LZΤMax (Lmax), LZΤMin (Lmin)
|
Event Audio Recording (optional)
|
Format
|
16-bit .wav
|
Sample Rate
|
8 kHz
|
Recording Time
|
Fixed: 2 s pre-trigger and 10 s post-trigger
|
Trigger Source
|
LAS, LAF, LCS, LCF, LAeq,1s, LCeq,1s
|
Trigger Level
|
40 – 140 dB, selectable
|
Back To Top >>
|
|